How to debug a natural gas wall-hung boiler
With the arrival of winter, natural gas wall-hung boilers are important equipment for home heating, and their commissioning and use have become a hot topic recently. The following is a compilation of hot content on the debugging of natural gas wall-hung boilers in the past 10 days across the Internet, combined with structured data to provide you with a detailed guide.
1. Preparations before commissioning of natural gas wall-hung boiler

Before debugging the natural gas wall-hung boiler, make sure that the following preparations have been completed:
| Project | Check content |
|---|---|
| gas supply | Confirm that the gas valve is open and there is no abnormality in the gas meter |
| Water pressure check | The water pressure of the wall-mounted boiler should be maintained between 1-1.5Bar |
| Power connection | Make sure the power socket is normal and the wall-hung boiler is powered on |
| Exhaust system | Check whether the flue is installed securely and without blockage |
2. Debugging steps for natural gas wall-hung boiler
The following are the specific steps for debugging a natural gas wall-hung boiler:
| steps | Operating Instructions |
|---|---|
| 1. Turn on the computer | Press the power button and the wall-mounted boiler enters standby mode. |
| 2. Mode selection | Choose heating or hot water mode and set according to your needs |
| 3. Temperature setting | Adjust heating temperature (50-60℃ recommended) and hot water temperature (40-45℃ recommended) |
| 4. Exhaust water pump | Open the water pump exhaust valve, exhaust the air and close it |
| 5. Ignition test | Observe whether the ignition is normal and whether the flame is stable |
3. Common problems and solutions during debugging
Common problems and solutions reported by recent users are as follows:
| question | Reason | Solution |
|---|---|---|
| Wall mounted furnace does not ignite | Insufficient gas supply or igniter failure | Check the gas valve and contact after-sales service |
| Water pressure is too low | The system is leaking or water is not replenished in time | Add water to 1-1.5Bar and check the pipeline |
| Too much noise | There is air in the water pump or the installation is unstable. | Vented or reinforced mounting bracket |
| Poor heating effect | Temperature set too low or system clogged | Turn up the temperature and clean the filter |
4. Precautions after commissioning of natural gas wall-hung boiler
After debugging is completed, you need to pay attention to the following matters to ensure the normal operation of the wall-hung boiler:
| Things to note | Description |
|---|---|
| Regular inspection | Check water pressure and gas lines monthly |
| Cleaning and maintenance | Clean heat exchangers and filters once a year |
| Security protection | Install carbon monoxide alarms and ensure ventilation |
| Energy saving suggestions | Lower the temperature at night and use the timer function wisely |
5. Recent hot topics: Intelligent trend of natural gas wall-hung boilers
In the past 10 days, the intelligent discussion on natural gas wall-mounted boilers has become a hot topic. Here are the features that users care about:
| Smart functions | heat index |
|---|---|
| Mobile phone remote control | 85% |
| Voice assistant linkage | 72% |
| Adaptive energy saving mode | 68% |
| Fault self-diagnosis | 63% |
With the above structured data and detailed instructions, you can easily complete the debugging of the natural gas wall-hung boiler. If you encounter complex problems, it is recommended to contact professional after-sales personnel to handle them.